Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Mechanical Heat Pump Didactic Equipment Thermal Training Equipment

ASR6128 Mechanical Heat Pump Didactic Equipment Thermal Training Equipment

Specification

investigation of a heat pump with a water circuit as load

refrigeration circuit with compressor, evaporator with fan, thermostatic expansion valve and coaxial coil heat exchanger as condenser

hot water circuit with pump, tank and condenser as heater

additional cooling via pipe coil in the hot water tank and external cooling water

record and display of all relevant measured values

refrigerant mass flow rate calculated in the software from recorded measured values

software for data acquisition via USB under Windows 7, 8.1, 10

refrigerant AR513A, GWP: 631

Technical data

Compressor

refrigeration capacity: 372W at 7,2/55°C

power consumption: 205W at at 7,2/55°C

Coaxial coil heat exchanger (condenser)

refrigerant content: 0,55L

water content: 0,3L

Finned tube evaporator

transfer area: approx. 0,175m2

Pump

max. flow rate: 1,9m3/h

max. head: 1,4m

Hot water tank volume: approx. 4,5L

 

Refrigerant: AR513A

GWP: 631

filling volume: 1kg

ACO2-equivalent: 0,6t

 

Measuring ranges

pressure: 2x -1…15bar

temperature: 4x 0…100°C, 2x -100…100°C

power: 0…6000W

flow rate: 0…108L/h (water)

flow rate: 10…160L/h (cooling water)

flow rate: 0…17kg/h (refrigerant)

 

230V, 50Hz, 1 phase; 230V, 60Hz, 1 phase

120V, 60Hz, 1 phase

UL/CSA optional

 

Dimensions and weight

LxWxH: 1630x800x1900mm

Weight: approx. 195kg

Electricity meter: Watt-hour type recording

electrical input to the compressor using a digital wattmeter

 

designed to allow students to gain a common understanding and assessment of performance and

characteristics of a heat pump operating on a steam compression cycle and with an electric drive

compressor, and is suitable for all levels of the course, from professional education to students.

Atmospheric air is of poor quality

 

Work is introduced as electrical energy

into a hermetically sealed compressor

 

Panel: High quality ABS.

Compressor: fully sealed single cylinder

reciprocating type. Engine displacement about 8.85 cm³ revolutions

Condenser: water refrigerant

 

Fluid receiver: with valves. Contains all refrigerant charge if required.

Evaporator: air to refrigerant

 

Digital thermometer: resolution 0.1 ° C, with switch on select from six thermocouples

Flow meters x 2: type of variable area – indicate

AR134a and AH2O costs.

Gauges x 2: to indicate the pressure of AR134a to the evaporator and condenser.

 

Safety Features: – High Pressure Capacitor Switch

and compressor thermal switch. – Residual current switch. – Combined bipolar trunk

circuit breaker and overload disconnected

Scroll to Top