Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Installation technology: losses in valves and fittings Thermal Laboratory Equipment

ASR3017 Installation technology: losses in valves and fittings Thermal Laboratory Equipment for college, university.

ASR3017 Installation technology: losses in valves and fittings Thermal Laboratory Equipment

Brand: ShouldShine

Model:ASR3017

Learning Objectives / Experiments

– pressure losses in valves and fittings

– measuring the pressure difference

– effect of the valve orifice shape on the pressure loss

– effect of the flow velocity

– determination of resistance coefficients

– comparison between experiment and calculation

Specification

[1] investigation of the pressure losses at various shutoff valves and fittings

[2] pipe elements are commercially standard components in heating, sanitary engineering

[3] clear panel mounted on a sturdy, movable frame

[4] pipe sections can be individually selected via ball valves

[5] water connections with quick-release couplings

[6] flow can be adjusted via valves

[7] flow measurement using rotameter

[8] differential pressure measurement via differential pressure meter with display

Technical Data

Ball valve, plastic, transparent,

Ball valve, steel,

Angle seat valve,

Screw-down valve,

Gate valve, diameter

Differential pressure meter

Measuring ranges – flow rate: 200…1700L/h – pressure: -200…200mbar

Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 90kg

Required for Operation Water connection, drain