ASR3004 Gas Cyclone engineering educational equipment Fluids Engineering Training Equipment
The unit shall perform the following experiments and investigations:
Learning Objectives / Experiments
influence of solid content and volumetric air flow rate on
pressure loss at the cyclone
degree of separation
separation function and separation size (with suitable analysis device)
comparison of pressure loss and degree of separation with theoretically calculated values
Specification
[1]solid separation from gases with a cyclone
[2]cyclone with tangential inlet
[3]metering of feed material into the air flow with a disperser
[4]air flow generation by fan; adjustment by valve
[5]tanks for feed material and coarse material
[6]1 filter at air inlet and 1 filter for fine material at air outlet
[7]recording of differential pressure, volumetric air flow rate and temperature
Technical Data Cyclone
height: approx. 250mm
diameter: approx. 80mm
immersion tube diameter: approx. 30mm Fan
Volumetric flow rate: max. 600m³/h
power consumption: approx. 3600W Tanks
feed material: 15mL
coarse material: 700mL Measuring ranges
cyclone differential pressure: 0…100mbar
volumetric flow rate (air): 10…100m³/h
temperature: 0…60°C
Dimensions and Weight
LxWxH: 1520x790x1800mm (trainer) Weight: approx. 160kg (trainer) LxWxH: 660x510x880mm (fan) Weight: approx. 33kg (fan)
Material of construction: stainless steel