ASR292 Experiments With A Radial Compressor Vocational Training Tools And Equipment Hydrodynamics Lab Equipment
1.Description
Radial compressors are used to compress gases. The medium is drawn in axially to the drive shaft by the rotation of the rotor and flows through the rotor rotating at high speed. By means of centrifugal force, the medium is accelerated towards the outer edge and is compressed in this manner.
The experimental unit provides the basic experiments to get to know the operating behaviour and the important characteristic variables of radial compressors.
features a two-stage radial compressor with variable speed via a frequency converter, an intake pipe and a delivery pipe. The intake and delivery pipes are transparent. A protective plate placed in front of the inlet of the intake pipe prevents larger objects from being drawn in or the clogging of the intake opening. The air flow is adjusted by a throttle valve at the end of the delivery pipe.
The experimental unit is fitted with sensors for pressure, temperature and speed. The flow rate is determinated via differential pressure measurement on the intake nozzle.
2.Technical details
Specification
Functioning and operating behaviour of a radial compressor
Two-stage radial compressor with drive motor
Variable speed via frequency converter
Transparent intake and delivery pipes
Throttle valve for adjusting the air flow in the delivery pipe
Protecting plate at air inlet for undisturbed air flow
Determination of flow rate
Display of differential pressures, flow rate, speed, electrical power consumption and hydraulical power output, temperatures and efficiency
Due to integrated microprocessor-based instrumentation no additional devices with error-prone wiring are required
Technical data
Intake pipe
Inner diameter: 44mm
Delivery pipe
Inner diameter: 34mm
Two-stage radial compressor
Power consumption: 1000W
Speed: 1000…16000min-1
Max. volumetric flow rate: 180m3/h
Max. pressure difference: 235mbar
Measuring ranges
Differential pressure (stage 1 / stage 2): 0…350mbar
Flow rate: 0…120m3/h
Temperature: 2x 0…100°C
Speed (compressor): 0…21000min-1
Electrical power consumption: 0…1000W
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional