Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Educational Unit for Training on Electrical Engineering Principals (Lighting Circuits & Electric Switches) educational lab equipment Automatic Trainer

AZE5102 Educational Unit for Training on Electrical Engineering Principals (Lighting Circuits & Electric Switches) educational lab equipment Automatic Trainer

Experiments that could be conducted:

Circuit of Electric Lamp – Not Controlled

Single Control Circuit of an Electric Lamp

Power Outlet (Socket) Circuit

Single Control Circuit of an Electric Outlet (Socket)

Single Control Circuit of an Electric Lamp & Non-Controlled Socket

Single Control Circuit of a group of Lamps connected in series

Single Control Circuit of a group of Lamps connected in parallel

Single Control Circuit of 2 groups of Lamps

Single Control Circuit of a Group of Lamps and a Socket

Double Control Circuit of a Group of Lamps

Triple Control Circuit of a Group of Lamps

Quadruple Control Circuit of a Group of Lamps

Double Control Circuit of a Group of Lamps with Dimmer

Triple Control Circuit of a Group of Lamps with Dimmer

Single Control Circuit of a Fluorescent Lamp

Single Control Circuit of 2 Fluorescent Lamps connected in Parallel

Single Control Circuit of an Ordinary Lamp and a Fluorescent One

Single Control Circuit of 2 Fluorescent Lamps

Circuit for Testing Inspected Faults in Different Switches

Circuit for Testing Inspected Faults of Lamps

Single Control Circuit of a Bell

Double Control Circuit of a Bell

Single Control Circuit of 2 Bells with an Operating switch for each.

 

Components of the Trainer

Electric Switches

Two Way Switch

Intermediate Switch

Single pole one way Switch

Push button Switch

Double pole one way Switch.

Dimmer

Electric Loads

Incandescent and energy saving bulbs.

Fluorescent lamps.

Starters and conventional ballast and electronic transformers.

Low voltage halogen lamps with ferromagnetic transformer and

LED lamps

Electronic Bell

Emergency Lighting

3 electric outlets

Power Feeding Line, Multi-Points

Switch Test Unit

Lamp Test Unit

Loaded outlet

Transformer 12 Volts

Emergency Stop

Main Circuit Breaker

Overload

Fuse

2 Circuit Breakers

Main Power Feeding Cable

Drawers for Storage

 

Attachments

Fuse, 25 Amp

2 Energy Saving Bulbs

2 Incandescent Lamps

2 Fluorescent Lamps, 60 cm

2 Fluorescent Lamps, 30 cm

30 Colored Cables

3 Starters

Remote Control

 

Electric Supply

Single Phase , 220 Volts, 50 Hz

Dimensions & Weight (approximate)

180 Cm x 80 Cm x 180 Cm

250 Kg

Scroll to Top