ACE600 Continuous Rectification Teaching Equipment Heat Transfer Lab Equipment
Distillation is used to separate liquid mixtures made up of individual liquids that are soluble in one another. Rectification refers to distillation in a counterflow. Ethanol/water is recommended as the liquid mixture for the CE 600.
A sieve tray column, a bubble cap tray column and a packed column are available. The packed column is filled with Raschig rings. Each column has three connections at different heights for the feed. The top product is condensed using a condenser and a phase separation tank. Part of this condensate is collected in a tank as product while the rest is fed back into the column. The reflux ratio is adjusted using valves. The bottom product can be collected in two tanks. A heat exchanger allows the feed to be preheated by the bottom product carried away from the column.
Relevant measured values are recorded by sensors. The composition of the feed and products is determined via an areometer based on the difference in density between ethanol and water.
The trainer is operated and controlled by the integrated PLC with touch screen. The measured values can be transmitted via LAN to a PC where they can be analysed using the software. By means of an integrated WLAN router, the trainer can additionally be operated and controlled via one end device and the user interface can be displayed on numerous end devices (screen mirroring). Menu navigation is independent of the user interface shown on the touch screen of the trainer. Different user levels with different functions are available on the end device. Data acquisition on end devices is possible via the network.
Specification
continuous and discontinuous rectification
packed, sieve tray and bubble cap tray column, interchangeable
device control with PLC, operation via touch screen or an end device
screen mirroring: possible to mirror the user interface on numerous end devices, data acquisition via network
3 feed inlets and 8 temperature sensors per column
sieve tray and bubble cap tray column with 8 trays
packed column with Raschig rings
vacuum mode possible with diaphragm pump
electrically heated evaporator
heat exchanger for bottom product cooling due to feed preheating or cooling water
condenser and phase separation tank for top product
closed cooling water circuit with water/air cooler
adjustment of reflux ratio using valves
software for data acquisition via LAN under Windows 8.1, 10
Technical data
Columns
height x inner diameter: 780x50mm
Feed pump
max. flow rate: 320mL/min
Cooling water pump
max. flow rate: 10L/min
Diaphragm pump: final vacuum approx. 213mbar abs.
Tanks feed: 2x approx. 5L bottom product: 2x approx. 5L top product: approx. 1,9L
Heat transfer surfaces
feed preheating/bottom cooling: approx. 0,03m2
top product condenser: approx. 0,04m2
Measuring ranges
temperature: 33x 0…150°C
pressure sensor: 2x 0…2,5bar (column), 1x -1…1bar
manometer: -1…0,6bar reflux ratio: 0…100% power: 0…4kW (heater) flow rate: 30…320L/h (cooling water) density: 0,7…1g/mL 400V, 50Hz, 3 phases 400V, 60Hz, 3 phases; 230V, 60Hz, 3 phases
UL/CSA optional
Dimensions and weight
LxWxH: 1905x790x2200mm Weight: approx. 400kg