ASR362 Comparison Of Pumps engineering teaching equipment Fluid Mechanics Experiment Equipment
1.Description
The experiments familiarise students with various pump types, such as centrifugal and positive displacement pumps.
The trainer includes two centrifugal pumps, one piston pump as a positive displacement pump and a self-priming side-channel pump. The side-channel pump works primary as a centrifugal pump and, depending on liquid level, can also act as a Positive displacement pump. This means, as a special feature, the side-channel pump also permits gases to be pumped.
The pump is investigated pumps water in a closed circuit. In the process, the performance data of the pump and pressure losses in the pipeline are recorded. The centrifugal pumps can also be operated in parallel or in series configuration. Each pump is driven by a All of the motors of the centrifugal pumps is variably adjustable by a frequency converter. All motors are mounted on swivel bearings, so the torque can be measured by way of a force sensor, enabling the mechanical drive power Output to be determined.
One free position is followed equipped with a reversible three-phase AC motor with variable speed. This position can be used for mounting of any pump.
Experiments demonstrate the basic operating lessons of various pump types.
2.Technical details
Specification
Experiments relating to key issues in pump engineering
Comparison of various pump types: centrifugal pump, piston pump, side-channel pump
Operation of centrifugal pumps in parallel or series configuration
Free position for additional pump
Three-phase AC motors for centrifugal pumps and additional motor with variable speed by frequency converter
Technical data
Centrifugal pump 2x
Max. flow rate (Q): 300L/min
Max. head (H): 16,9m
Nominal speed: 2900min-1
Three-phase AC motor 2x, for centrifugal pump
Power output: 1,1kW
Side-channel pump, self-priming, one-stage
Q: 83, 3L/min, H: 50m
Nominal speed: 1450min-1
Three-phase AC motor for side-channel pump
Power output: 1,1kW
Piston pump
Q: 17L/min, H: 60m
Nominal speed: 405min-1
Three-phase AC motor for piston pump
Power output: 0,55kW
Three-phase AC motor, additional motor, reversible
Power output: 0,75kW
Speed range: 750…3000min-1
Measuring ranges
Flow rate: 0…500L/min
Pressure (inlet): -1…1,5bar
Pressure (outlet): 0…10bar
Torque: 0…15Nm
Speed: 0…3000min -1
Pump electrical power consumption: 0…2kW
400V, 50Hz, 3 phases
400V, 60Hz, 3 phases
230V, 60Hz, 3 phases