AZM7145 Characteristic variables of Hydraulic Turbo machine teaching aid equipment Hydrodynamics Lab Equipment
- determining characteristic variables of a centrifugal pump
determining characteristic variables of water turbines together with the accessories pelton turbine and Francis turbine - experiments on a pump in a closed water circuit with storage tank and flow control valve to adjust the back pressure
- experiments on turbines: closed water circuit for supplying turbines
pipes and fittings made of PVC - 3-phase AC motor for pump with variable speed via frequency converter
non-contact speed measurement at the turbine shaft and force sensor at the brake for measuring the torque - digital displays for pressures, flow rate, speed and torque
Technical Data
Standard centrifugal pump
– max. head: 23,9m
– max. flow rate: 31m³/h
Drive motor with variable speed
– power output: 2,2kW
– speed range: 0…3000min-1
Storage tank: 250L
Measuring ranges
– pressure: 2x 0…4bar abs.
– flow rate: 0…40m³/h
– torque: 0…20Nm
– speed: 2x 0…4000min-1
Dimensions and Weight
LxWxH: 1900x790x1900mm
Weight: approx. 243kg
Required for Operation
230V, 50/60Hz, 1 phase or 230V, 60Hz/CSA, 3 phases