Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Combilent Group develops and delivers state of the art

RF Critical Communication Infrastructure Products

Combilent Transmitter Combiners are designed to facilitate site optimization and maintenance. They include remote and continuous configuring, features for monitoring and controlling antenna RF power (forward and reflected), antenna return loss (VSWR) and more.

DS18818 – Cavity Combiner
  • Combilent provide a line of compact cavity combiners featuring integrated antenna power monitoring. Models are available covering UHF 350-512 MHz and 700/800/900 MHz bands.

  • Alarms are generated upon high antenna VSWR and/or high temperature and are user configured through Ethernet or SNMP.

  • Ethernet, web interface SNMP, and SYSLOG enabled monitors provide information on forward power, reflected power, antenna VSWR and heat sink temperature while also allowing for easy factory or field tuning using only the base station radio and a PC.

  • All modules are broad band (20 MHz) and symmetrical.

  • Picture shows a 4 Ch. Cavity Combiner with integrated Frequency Selective Power Monitor and expanded by additional 2 Ch. Cavity Combiner.

DS18818 – Cavity Combiner
  • Combilent provide a line of compact cavity combiners featuring integrated antenna power monitoring. Models are available covering UHF 350-512 MHz and 700/800/900 MHz bands.

  • Alarms are generated upon high antenna VSWR and/or high temperature and are user configured through Ethernet or SNMP.

  • Ethernet, web interface SNMP, and SYSLOG enabled monitors provide information on forward power, reflected power, antenna VSWR and heat sink temperature while also allowing for easy factory or field tuning using only the base station radio and a PC.

  • All modules are broad band (20 MHz) and symmetrical.

  • Picture shows a 4 Ch. Cavity Combiner with integrated Frequency Selective Power Monitor and expanded by additional 2 Ch. Cavity Combiner.

DS18825 – Tx Filter
  • Integrated milled one-block Tx filter units with compact dimensions and high levels of integration.

  • Less potential for loss, failure and intermodulation due to Combilent design innovations that incorporate less cables, components and connections.

  • Combilent filters feature optimized insertion loss, attenuation, bandwidth and selectivity to ensure ideal system performance.

  • Picture shows a Tx filter in a milled one-block unit.

DS21955 – Duplexer capabilities
  • Duplexers range in size and power handling capability, from two channel units to multi-channel high-power base station units, providing critical isolation between receiver and transmitter.

  • No tuning required (tuned to customer frequencies at our factory)

  • Picture shows a Duplexer with integrated Tx Power Monitor and RMC.

DS21955 – Filter capabilities
  • Integrated milled one-block Rx filter units with compact dimensions and high levels of integration.

  • Less potential for loss, failure and intermodulation due to Combilent design innovations that incorporate less cables, components and connections.

  • Combilent filters feature optimized insertion loss, attenuation, bandwidth and selectivity to ensure ideal system performance.

  • Picture shows an Rx filter with integrated RMC in a milled one-block unit.

DS15543 – TMA
  • Combilent’s TMA/TTA products offer the most and lightweight and compact form factor on the market for ease of installation and integration.

  • Quality manufactured, integrated one-block unit, ensuring less points of failure and lower noise figure from less cables, components and connectors.

  • Integrated filter (band pass or duplexer) and LNA with onboard surge protection.

  • System gain setting, visual indicators and relay alarm output at the Receive Multi-Coupler (RMC).

  • Rx distribution from the RMC (AC mains or DC power supplied).

  • Combilent TMAs are 50% more compact than industry-standard TMAs.

DS18855 – RMC
  • Combilent’s High Performance RMCs include high selectivity band-pass pre-selectors for protection against unwanted noise, as well as balanced amplification and an integrated DC back-up connection (+12V).

  • Designed for VHF, UHF and 700/800/900 MHz.

  • Gain control and status are visible on the front panel display.

  • The RMC parts are housed in a single chassis for rack-mounting in Base Transceiver Stations. Cable
    runs and cabling costs are minimized, and cable signal loss and noise figures are reduced.

  • Ethernet, web interface SNMP and syslog enable monitoring of system health and configuration of
    system gain.

  • Single band and dual band RMC versions are available (no TMA).

  • Picture shows an RMC with integrated Rx Filter, LNA, TMA Power Supply and Control Unit.

DS21736 – Tx Composite Power Monitor
  • Functions on one or two channels.

  • Measures the total RMS power of all signals in the system using a dual directional coupler, a switch selecting forward or reflected power and an RMS detector.

  • Ethernet / web-server SNMP enabled / SYSLOG.

  • Picture shows a Composite In-line Tx Monitor with ETH interface, integrated web-server, SNMP and relay alarm output

DS19788 – Tx Stand alone Frequency Selective Power Monitor
  • Frequency selective.

  • Supports up to 10 carriers of 50W each.

  • Passive intermodulation hardened.

  • Compact form factor, 2RU.

  • Ethernet / web-server SNMP / SYSLOG enabled.

  • Measures forward and reflected power, antenna VSWR and temperature.

  • Alarms are user configured via web interface or SNMP.

  • Picture shows a Stand-alone Frequency Selective Power Monitor with ETH interface, integrated web-server, SNMP and relay alarm output.

DS21093 – Rx VSWR Monitor
  • The RX Antenna VSWR Monitor attaches between the RMC and the RX antenna.

  • VSWR of the receiver antenna is monitored periodically, with data accessed through
    Ethernet, web server and SNMP.

  • The RX signal runs through the RX Antenna VSWR Monitor. It has low insertion loss
    and maintains signal integrity.

  • Picture shows an in-line Rx VSWR Antenna Monitor with ETH interface, integrated web-server, SNMP, and relay alarm output

Racking

  • Technical description

  • Block diagrams

  • Rack layouts

  • Complete system test data

  • Picture shows a racking solution for a 6 Ch. UHF Dual Band System

  • Technical description

  • Block diagrams

  • Rack layouts

  • Complete system test data

  • Picture shows a racking solution for a 6 Ch. UHF Dual Band System

TECHNICAL TESTING AND CALIBRATION SYSTEM FOR TOTAL STATIONS INSTRUMENTS
    • Check, calibrate and evaluate the quality of Total Station and Digital Levels through testing, measuring, identifying and evaluating errors: Vertical angle, horizontal angle and distance measurement of the Total Station; Deviation standard of Digital Levels
    • Initial check, periodic check and post-repair for electronic total stations with angular accuracy ≥ 1.5” and distance accuracy ≥ (1.5 + 2 ppm×D) mm; Level measuring devices have standard deviation ≥ 0.5 mm/1000 m.
    • Check and calibrate the standard deviation, vertical angle error, level angle error and distance measurement standard deviation of the electronic total station; Deviation, error of height difference value of leveling means
    • Powerful processing unit and specialized software to help acquire, analyze, and automatically calculate measurement data according to installed and established testing and calibration procedures to provide
Details
QUALITY TESTING SYSTEM, CALIBRATION OF METEOROLOGICAL INSTRUMENTS
  • Check and calibrate humidity measurement errors, temperature errors and self-recording time of air humidity measuring devices and sensor-type air temperature measuring devices
  • Check and calibrate resolution error, measurement error, return error, repeatability error and linearity of atmospheric pressure measuring devices with absolute zero point as reference point, indicator type digital and analog with measuring range ≤ 115 kPa and |k| ≥ 0.02 kPa
  • Check and calibrate the indicator, discrimination threshold at Vmin, error of wind speed measuring device with maximum speed up to 50 m/s, maximum allowable error: ± 5% FS
  • Powerful processing unit and specialized software to help acquire, analyze, and automatically calculate measurement data on temperature, humidity, pressure, wind speed according to established testing and calibration procedures. installed and set up to provide accurate results, helping Inspectors have an accurate and objective assessment of the tested equipment
  • Details
Scroll to Top