PERFORMANCE
- Crest Factor: 1.31 ~ 1.51
- Voltage adjustment range: (1±10%)Un
- Total Harmonic Distortion (THD) of Voltage Waveform: <2.5%
- Voltage recovery time: <0.1 s
- Transient voltage regulation: within ±12%
- Steady voltage regulation: within ±1 %
- Insulation: Class H
- Continuous duty
- Overload capacity: 110% rated load for 1 hour continuously
- Dynamic balancing grade: G2.5 (IS01940)
- Starting Current: < 1.5*In
- Operating temperature: -5°C – 40°C
- Humidity: < 85%
- Elevation above sea level: < 1000m
Continuous Rating |
|
Motor Generator Set Model |
Anx26-MGS |
Input Frequecy |
50 Hz |
Output Frequency |
400 Hz |
Output Power |
62,5 kVA |
Motor Power |
70 kW |
Motor Pole Nos. |
4-pole |
Generator Pole Nos |
24-pole |

GENERAL SPECIFICATIONS |
|
Model |
ANX26-MGS |
Reinforced Common Base |
Motor Installed |
Overall Structure |
Common-shaft mounting |
Type of Generator |
Rotary shaft |
Winding connection of motor |
Delta |
Type of Motor |
Cylindrical shaft |
Winding Connection of generator |
Wye with neutral |
Enclosure |
Sound-proof/weather-proof enclosure as option |
Starting Mode |
Y-delta starting or soft starting as options |
Operating temperature |
-5 °C – 40 °C |
Humidity |
< 85% |
Elevation above sea level |
< 1000m |
Digital Control Panel |
Installed |
Motor Parameters |
|
Brand |
EMS |
Rated power |
70 kW |
Rated frequency |
50 Hz |
Pole number |
4 poles |
Rated voltage |
3-phase 380V (phase to phase) |
Rated current |
125A |
Max starting current |
1.5 times rated current |
Power Factor |
0.9 |
Starting Method |
Y-∆ starting |
Efficiency |
90% |
Generator Parameters |
|
Rated Frequency |
400 Hz ±1 % |
Rated Power |
62.5 kVA |
Rated Voltage |
3-phase 208V (phase to phase) |
Rated Current |
173.5 A |
Pole Number |
24 poles |
Voltage recovery time |
0.1 s |
Voltage waveform THD |
2.5 % |
Efficiency |
90% |
Crest Factor |
1.31 – 1.51 |
Rotation speed |
2000 rpm |
Included accessories |
|
Surge Protection Device (SPD) |
Yes |