decatron
OG-9 is a counting decatron with a directional cathode for operation in
calculating and calculating-solving devices and for
frequency division. Filled with an inert gas with a deionizing impurity.
The cathodes are cold and inactive.
They work in any position.
The countdown is visual, according to the position of the discharge glow;
for 0.1, 5 and 9 cathodes– electric, output
voltage at the cathode resistance. The indication is made through the dome of the cylinder.
The decoration is glass, with a base (RSH5-1).
Basic parameters:
Conversion factor—10
Power supply voltage—>400 V (according to some sources 450 V)
Discharge voltage—<375 V
Discharge maintenance voltage—<220 V
Bias voltage on the subcathodes—40 V
Voltage amplitude of the reset pulse—135…165 V
Control pulse data:
account speed*—0,001 Hz…2 kHz
amplitude—120-170 V
duration—160 microseconds
Operating time—>1000 h
Glow—orange-red
Weight—70 g
Maximum allowed parameters:
Current in the anode circuit—0.3…0.4 mA
The highest resistance of the cathode load—39 kOhm
Output voltage at the cathodes—20 V
Operating temperature range—/-60 … +70°C
* The permissible operating time of the decatron is no more than 1 hour, subject to subsequent operation at frequencies of 50 Hz and higher in
for 1 hour, and the total standing time of the discharge should not exceed 50 hours.