ASR282 Experiments With An Axial Fan equipment teaching Hydrodynamics Laboratory Equipment
1.Description
The medium to be transported is drawn in axially to the drive shaft of the axial fan by the rotation of the rotor. The medium flows through the rotor and is discharged axially behind the rotor.
The experimental unit provides the basic experiments to get to know the operating behaviour and the important characteristic variables of axial fans.
features an axial fan with variable speed via an integrated controller, an intake pipe and a delivery pipe. The transparent intake and delivery pipes are fitted with guide plates for flow guidance. A flow straightener in the intake pipe serves to calm the air. The air flow is adjusted by a throttle valve at the end of the delivery pipe.
2.Technical details
Specification
Functioning and operating behaviour of an axial fan
Axial fan with electronically commutated drive motor
Variable speed via integrated controller
Transparent intake and delivery pipes
Throttle valve to adjust the air flow in the delivery pipe
Determination of flow rate
Display of differential pressure, flow rate, speed, electrical power consumption and hydraulical power output, temperature and efficiency
Due to integrated microprocessor-based instrumentation no additional devices with error-prone wiring are required
Technical data
Intake pipe
Inner diameter: 110mm
Length: 275mm
Delivery pipe
Inner diameter: 110mm
Length: 310mm
Axial fan
Power consumption: 90W
Nominal speed: 9500min-1
Max. volumetric flow rate: approx. 600m3/h
Max. pressure difference: approx. 700Pa
Measuring ranges
Differential pressure: 0…1800Pa
Flow rate: 0…1000m3/h
Temperature: 0…100°C
Speed: 0…9999min-1
Power consumption: 0…500W
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional
Required for operation
PC with Windows