ASR6128 Mechanical Heat Pump Didactic Equipment Thermal Training Equipment
Specification
investigation of a heat pump with a water circuit as load
refrigeration circuit with compressor, evaporator with fan, thermostatic expansion valve and coaxial coil heat exchanger as condenser
hot water circuit with pump, tank and condenser as heater
additional cooling via pipe coil in the hot water tank and external cooling water
record and display of all relevant measured values
refrigerant mass flow rate calculated in the software from recorded measured values
software for data acquisition via USB under Windows 7, 8.1, 10
refrigerant AR513A, GWP: 631
Technical data
Compressor
refrigeration capacity: 372W at 7,2/55°C
power consumption: 205W at at 7,2/55°C
Coaxial coil heat exchanger (condenser)
refrigerant content: 0,55L
water content: 0,3L
Finned tube evaporator
transfer area: approx. 0,175m2
Pump
max. flow rate: 1,9m3/h
max. head: 1,4m
Hot water tank volume: approx. 4,5L
Refrigerant: AR513A
GWP: 631
filling volume: 1kg
ACO2-equivalent: 0,6t
Measuring ranges
pressure: 2x -1…15bar
temperature: 4x 0…100°C, 2x -100…100°C
power: 0…6000W
flow rate: 0…108L/h (water)
flow rate: 10…160L/h (cooling water)
flow rate: 0…17kg/h (refrigerant)
230V, 50Hz, 1 phase; 230V, 60Hz, 1 phase
120V, 60Hz, 1 phase
UL/CSA optional
Dimensions and weight
LxWxH: 1630x800x1900mm
Weight: approx. 195kg
Electricity meter: Watt-hour type recording
electrical input to the compressor using a digital wattmeter
designed to allow students to gain a common understanding and assessment of performance and
characteristics of a heat pump operating on a steam compression cycle and with an electric drive
compressor, and is suitable for all levels of the course, from professional education to students.
Atmospheric air is of poor quality
Work is introduced as electrical energy
into a hermetically sealed compressor
Panel: High quality ABS.
Compressor: fully sealed single cylinder
reciprocating type. Engine displacement about 8.85 cm³ revolutions
Condenser: water refrigerant
Fluid receiver: with valves. Contains all refrigerant charge if required.
Evaporator: air to refrigerant
Digital thermometer: resolution 0.1 ° C, with switch on select from six thermocouples
Flow meters x 2: type of variable area – indicate
AR134a and AH2O costs.
Gauges x 2: to indicate the pressure of AR134a to the evaporator and condenser.
Safety Features: – High Pressure Capacitor Switch
and compressor thermal switch. – Residual current switch. – Combined bipolar trunk
circuit breaker and overload disconnected